- 1000m/s2
- Protection Class: IP67(EN60947-5-1)
- Allowable Operation Frequency: Up to 30 times / min
- Allowable Operating Speed: 1 to 500 mm / s (D4N-1120)
- Operation Ambient Temperature (?): -30 to +70 (but no freezing)
- Conduit mouth size: G1 / 2 (1 conduit type)
- Insulation Resistance (M?): over 100
- Conditional Short-Circuit Current : 100A(EN60947-5-1)
- Vibration Resistance (Mis-operation): 10-55Hz 0.75mm single amplitude
- Shock Resistance (Mis-operation): 300m/s2
- Mechanical Durability: 15 million times or more
- Ambient Humidity to Use: 95% RH or less
- Electrical Durability: 500,000 operations or more (250 VAC, 3 A, resistance load), 300,000 operations or more (250 VAC, 10 A, resistance load)
- Rated Frequency (Hz): 50/60